    Data Centre Overview

    Standingwave's infrastructure is located in two diverse world-class Data Centre facilities in London's Docklands. Our data centres meet the high security and protection demands of any Internet presence. Our Data Centres have redundant systems for connectivity, electrical power, air conditioning and fire suppression to ensure that your Internet presence is always available. The Data Centres are monitored 24 hours per day, 7 days per week and 365 days per year. All staff are committed and trained to provide you with continual, high-level network monitoring and load management of your connection. In addition, there is engineering support for outage response and network performance analysis.

    Power & Air Conditioning

    Right from the start, the power supplies were designed with several criteria in mind: very high capacity, stability, reliability and scope for easy expansion. The facility has a 2-Megawatt power supply - that's enough power to light up London's Wembley Stadium ten times over (if it was still there). Backing that up are dedicated Uninterruptible Power Supply (UPS) systems plus two further diverse mains supplies (scalable for future growth) with circuit breaker protection, and an on-site generator in the unlikely event of long-term power outages.

    Fire & Security

    Security is obviously an essential consideration for our customers housing their precious data externally. We have a high-security system that includes 24 x 7 monitoring by on-site personnel, video camera surveillance and a security breach alarm. Access to the Internet data centre is by card key, and each instance of opening of StandingWaves areas is logged by time and date.

    Data Centre - Detailed Specifications

    • 11,000 reduced to 415/240 volt 3-phase supply at 50Hz
    • 1750 kva Generator
    • UPS Backup System - redundant parallel formation
    • Downflow air conditioning units to guarantee stable temperature
    • Separate aircooled and DX air conditioning systems
    • 2 Megawatts of power to data floor
    • 2 Diverse Power Supplies
    • Very Early Smoke Detection Apparatus (VESDA)
    • FM200 fire suppression system
    • Underfloor water detection system
    • CCTV system covering all entrances / exits and main areas
    • 24-hour video recording
    • Full perimeter alarm
    • Proximity card access system
    • Visual check on all persons entering the data floor